Gold tester, XRF Analyzer & Gold Testing Machine Manufacturer, Supplier, Factory China
VRAY Instrument Limited

X Ray Gold Tester

What is an X-ray Gold Tester?

An X ray Gold Tester (XRF Analyzer) is a sophisticated, non-destructive device that uses X-ray Fluorescence technology to precisely determine the elemental composition and purity of gold and other precious metals. It works by exciting the sample with X-rays, causing atoms to emit characteristic secondary X-rays which are then detected and analyzed to quantify elemental percentages. These testers are crucial in jewelry, pawn shops, refineries, and recycling to verify authenticity, ensure accurate valuations, prevent fraud, and maintain quality control. They deliver immense value by building trust, streamlining operations, and safeguarding investments.

Best X Ray Gold Tester for Sale from VRAY in Different Models

Page 1 of 1

VRAY X-ray Gold Tester Solutions: Comprehensive Overview

At VRAY, we leverage 17 years of manufacturing expertise to provide a comprehensive range of X ray Gold Testers, engineered for precision, reliability, and ease of use. Our solutions cater to diverse needs, from portable on-site analysis to high-accuracy laboratory verification.

Our Core Models & Specifications:

VR-T7 (Desktop, Premium)

  • Priced at $20,000-$22,000, this model offers a 0.01% accuracy for 9999 gold using a high-sensitivity SDD detector. It features a 50W micro-focused X-ray tube, a φ1.5mm collimator, a 5-million-pixel CMOS camera with 40x-160x magnification, and a manual XY platform. Test time is just 30 seconds.

VR-M5 (Portable)

  • Ranging from $15,000-$18,000, the VR-M5 is designed for mobility (4.1Kg) while maintaining excellent 0.05% accuracy for 9999 gold with a customized USA Si-Pin detector. It boasts a 5.7" retractable touch screen, built-in camera, 32GB memory, and supports USB/Bluetooth data transmission. Test time is 30 seconds. Ideal for field use across wide temperatures (-20℃~50℃).

VR-X3 (All-in-one Desktop, Economical)

  • At $6,000-$7,000, the VR-X3 offers 0.1% accuracy for 999 gold with a gas proportional detector. It tests common elements (Au, Ag, Cu, Pt, Pd, Ir, Cd) in solids, with a test time of 50 seconds. It includes a built-in industrial computer for a streamlined experience.

Key Technical Features Across Models:

  • All VRAY X ray Gold Testers utilize non-destructive XRF technology. They are equipped with dedicated T-shaped radiators for efficient heat dissipation, ensuring continuous operation without cooling delays. Most models feature high-resolution cameras for precise sample positioning and detailed analysis.

Flexible Customization Options:

  • We offer flexible customization to meet specific business needs. For bulk orders (typically 5 units minimum), we provide logo customization, allowing seamless brand integration. Consult our team for other specific configuration requirements.

Comprehensive After-Sales Service:

VRAY is committed to long-term customer satisfaction. Our after-sales support includes:

  • Installation Guidance & Technical Training: Ensuring proper setup and confident operation.

  • Software Updates: For continuous performance enhancement.

  • 1-Year Hardware Warranty: Providing peace of mind.

  • Remote Guidance & Diagnosis: For rapid troubleshooting and support.

  • Software & Hardware Replacement: To minimize downtime.

  • On-site Engineer Service: For complex issues requiring direct intervention.

X-ray Gold Tester: Working Principle & Applications

VRAY X-ray gold testers use non-destructive XRF for precise gold purity and composition analysis. They serve crucial needs for:

  1. Jewelry Retailers: Instantly authenticate, identify karat levels (18K, 22K), building trust, preventing fraud.

  2. Recyclers/Pawnshops: Ensure accurate pricing with non-destructive tests, boosting deal success via reports.

  3. Manufacturers: Guarantee raw material purity, optimize alloy ratios for consistent quality control.

  4. Labs/Certification: Provide high-precision multi-element analysis, formal reporting for compliance.

  5. Collectors/Dealers: Verify authenticity, protect item value by detecting fakes without damage.

VRAY solutions deliver rapid, reliable data, empowering informed decisions, ensuring quality, and safeguarding investments across the precious metals sector.

X-ray Gold Tester: Working Principle & Applications

Operation and Maintenance Guide for X Ray Gold Tester

VRAY X-ray Gold Testers require daily 10-min preheat & strict calibration. Simply place sample, close door, and start for 30-second results, ready for print/save.

For maintenance, wipe casing daily, clean test window/vents. Maintain a dry, clean, ventilated environment (15-30℃,<70% humidity, no direct sun), and always use a voltage stabilizer/UPS.

Crucial precautions: Always close protective door before testing (X-ray safety). Never modify parameters/calibration. Avoid frequent power cycles. Ensure proper cooling. Do not move samples/open door during tests. Never touch detector window (costly damage). Following guidelines ensures safe, stable performance & extended lifespan.

Operation and Maintenance Guide for X Ray Gold Tester

X-ray Gold Tester: Pricing & Purchase Guide

VRAY offers diverse X-ray gold testers across various price points:

  • VR-X3 (All-in-one Desktop): $6,000-$7,000 (Economical)

  • VR-M5 (Portable): $15,000-$18,000

  • VR-T7 (High-end Desktop): $20,000-$22,000

Key purchase considerations include:

  1. Element Detection Range: Support for precious metals (Au, Ag, Pt, Pd, etc.) and alloying elements.

  2. Accuracy/Resolution: Expressed in ppm or % error (e.g., ±0.01%); lower values indicate higher sensitivity. SDD detectors are preferred.

  3. Test Speed: Result acquisition time (30-60s); faster speeds suit high-frequency use.

  4. X-ray Tube Power: Impacts penetration and speed; higher power generally means higher cost and energy consumption.

  5. Safety & Certification: Includes X-ray safety shielding, interlocked protective doors, and radiation license certification.

  6. Local & After-sales Service: Covers local maintenance, on-site support, training, and warranty period (recommended 1 year).

X-ray Gold Tester: Pricing & Purchase Guide

What You Should Know: X-ray Gold Tester Emergency Handling

VRAY understands the importance of stable equipment operation for our clients' businesses. Therefore, we have established a comprehensive and responsive after-sales service system, aimed at providing strong technical support and efficient solutions in emergencies, ensuring that equipment failures are promptly and properly handled to minimize client losses.

Common Handling Emergency/Sudden Situations:

For emergency situations that may arise during the use of VRAY X-ray Gold Testers, we offer the following professional handling solutions:

  • Software Issues: For problems such as unusable software, failed software updates, or upgrades, VRAY has a team of professional engineers ready to provide remote support at any time to quickly identify and solve customer software problems.

  • Hardware Issues: When hardware problems occur, such as X-ray tube damage, detector failure, abnormal high-voltage power module, or protective door sensor malfunction, VRAY offers two flexible solutions:

  1. Clients can choose to have accessories mailed to them, combined with detailed video tutorials, to solve the problems themselves with our clear guidance.

  2. For more complex issues or problems that cannot be resolved remotely, VRAY will dispatch engineers to the site to provide professional troubleshooting and repair, ensuring the equipment returns to normal operation as quickly as possible.

What You Should Know: X-ray Gold Tester Emergency Handling

X-ray Gold Tester: Operation Guidelines vs. Hazards


Correct Operation Guidelines

Hazards of Improper Operation

1. Startup & Calibration


Upon first power-on each day, strictly preheat for 10 minutes and perform calibration.

Skipping preheating and calibration may lead to inaccurate measurements or instrument instability.

2. Safety Operation


Always close the protective door securely before testing.

X-ray Leakage: Starting tests with the protective door not tightly closed may lead to X-ray leakage and radiation damage to the operator.

Never move the sample or open the protective door before testing is complete.

X-ray Exposure/Test Failure: Moving the sample or opening the door during testing may cause sample displacement, test failure, and potential X-ray exposure.

3. Power Management


It is recommended to use a regulated power supply or UPS to ensure stable voltage.

Equipment Damage/System Crash: Forcibly cutting power or frequently turning the machine on/off can easily damage the X-ray tube, high-voltage module, or hard drive, causing system crashes.

4. Environmental Requirements


Keep the equipment's working environment dry, clean, and well-ventilated, avoiding high temperature, high humidity, and dust.

Equipment Malfunction: Humid, hot, or dusty environments may cause device overheating, mainboard dampness, and detector malfunction/short-circuit.

5. Parameter Settings


Strictly follow the operation manual or manufacturer's training guidelines; do not privately modify parameter settings or calibration data.

Data Distortion/Factory Recalibration: Unauthorized modification of software parameters or calibration data can lead to data distortion; in serious cases, the software may require factory recalibration.

6. Detector Protection


Avoid touching the detector window (e.g., SDD protection film) with sharp objects or fingers.

High Maintenance Costs: Touching the detector window can damage the detector film, resulting in permanent detector damage and extremely high maintenance or replacement costs.

To view the correct operation guide for X ray gold tester, please watch our VRAY's X ray gold tester instructional video.


Contact us today

let us boost your business today!
  • Production Competency Production Competency
  • Warranty Assurance Warranty Assurance
  • Expert R&D Team Expert R&D Team
  • Competitive price Competitive price
  • Customization Excellence Customization Excellence
  • Quality Control Quality Control
All of your questions will be answered by our team in a very quick/effective way.
  • verify code

What did our happy clients say?

Hot Products